🔧 Power Up Your Safety Game!
The SIEMENS Q120DF 20-Amp AFCI/GFCI Dual Function Circuit Breaker is engineered for quick installation and enhanced safety. With a smart LED trip indicator and compatibility with Siemens load centers, this breaker ensures reliable performance and peace of mind for your electrical needs.
Brand | SIEMENS |
Current Rating | 20 Amps |
Product Dimensions | 5"D x 1"W x 3.5"H |
Circuit Breaker Type | AFCI |
Mounting Type | Plug-In Mount |
Number Of Poles | 2 |
UPC | 887621817329 |
Manufacturer | Siemens -HI |
Global Trade Identification Number | 00887621817329 |
Part Number | Q120DF |
Item Weight | 4 ounces |
Country of Origin | Philippines |
Item model number | Q120DF |
Is Discontinued By Manufacturer | No |
Size | 20-Amp |
Color | Black |
Style | Breaker |
Material | Plastic |
Pattern | Cardboard Packaging |
Shape | Triangle |
Voltage | 120 Volts |
Item Package Quantity | 1 |
Number Of Pieces | 1 |
Included Components | Q120DF |
Batteries Included? | No |
Batteries Required? | No |
Warranty Description | 1 Year |
R**L
Siemens AFCI/GFI breaker
Nice when needing afci and GFI protection to meet NEC requirements
P**.
Siemens Q120DF Dual (AFCI/GFCI)
If you have a Siemens Load Center (Circuit Breaker Box), you need this.This breaker protects both against Arc Flash and Ground Fault.The Arc Flash protects again bad wiring/connections that may arc protecting the house.The Ground Fault protects circuit outlets and switches that are near water and protects the person.Better than having a GFCI outlet since this is in the Load Center panel and out of site. And no buttons to reset(possibly with wet hands). Your outlet can now be a standard looking outlet.In my house they originally wired in the ugly GFCI outlets for around the kitchen. I took them out and used this kind of breaker. Wife likes the new look and so do I. Plus, now I have dual protection by taking out the standard breaker that was in the Load Center. Yes, it took some time to change the bathroom and kitchen circuits, but I am now safer with having added this dual function with arc flash and ground fault protection .Additionally, there was a counter light switch and that didn't have any protections. I took out the standard breaker and put this dual function breaker on that circuit, too, since I was concerned my wife might flip the counter lights on or off with wet hands. I can't replace the love of my life.
H**R
Perfect
This fits perfectly into our new siemens subpanel. Easy to install and great quality.
W**M
Just what I wanted.
Just what I wanted.
T**T
Works fine in my GE breaker panel
I have an old GE breaker panel, and needed to add a GFCI breaker on one of my circuits. This Siemens breaker fit fine, although it takes up a full 1" slot. Fortunately the 1/2" breaker I replaced this with had an adjacent empty 1/2" slot to accommodate it. I wish I could find a 1/2" breaker compatible with my GE breaker panel (only reason for 4 stars rather than 5).
R**H
Like-for Like Replacement
I had a 1 year old Q120DF 20 Amp in place that tripped below 20 Amps. This is a like-for-like model. It came with like new appearance. It was easy to install, trip tested successfully and has worked without tripping below 20 Amps.
A**X
Fit in my Murphy LC230PC panel
I'm happy that this fit in my Murphy LC230PC. I've not yet experienced any phantom trips.
P**N
Solves new AFCI and GFCI requirements
Depending on where you live, the inspector can be very strict on what types of outlets that must be installed on remodel work.I had several outlets that the inspector said needed AFCI protection and because they were within 6 feet of a sink also needed GFCI protection.He recommended using an AFCI breaker then adding tamper proof GFCI outlets. This setup can get expensive real quick.Fortunately I found these dual purpose breakers that provide both AFCI and GFCI protection on the entire circuit making installation easier and cheaper than the inspectors recommendation.I have installed several of these and have had no nuisance tripping issues so far. I did not install one on the fridge circuit as I've heard too many horror stories of unnoticed tripping and the food going bad. No problems on the microwave, computers and their UPS back ups, vacuum, or anything I have plugged in so far.The one issue I had was no fault of the breaker. It requires the neutral of the circuit to be screwed into the breaker itself. On two circuits the neutral was too short and couldn't reach the breaker and I did not wish to rearrange the breakers to get them closer.I found "Spliceline Orange (20pcs)" by Ideal here on Amazon that solved the issue. Simply strip about half an inch on the neutral extension wire and push into the connector. They are UL listed for use inside panels and electrical boxes.If I find anything that does trip these breakers, I will update my review.